排油注氮灭火系统防爆防火灭火基本原理
排油注氮灭火系统防爆防火灭火基本原理:
The basic principles of explosion-proof and fire extinguishing system for oil drain and nitrogen injection fire extinguishing system are as follows:
当变压器内部发生故障,油箱内部产生大量可燃气体,引起气体继电器动作,发出重瓦斯信号,断路器跳闸;变压器内部故障同时导致油温升高,布置在变压器上的温感火灾探测器动作,向消防控制柜发出火警信号。消防控制中心接到火警信号、重瓦斯信号、断路器跳闸信号后,启动排油注氮系统,排油泄压,防止变压器爆炸;同时,储油柜下面的断流阀自动关闭,切断储油柜向变压器油箱供油,变压器油箱油位降低。一定延时后(一般为3s至20s),氮气释放阀开启,氮气通过注氮管从变压器箱体底部注入,搅拌冷却变压器油并隔离空气,达到防火灭火的目的。
When the internal fault occurs in the transformer, a large amount of combustible gas is produced inside the tank, causing the action of the gas relay, sending out heavy gas signals and breaking the circuit breaker; the internal fault of the transformer causes the oil temperature to rise at the same time, the temperature fire detector action on the transformer is arranged and the fire alarm signal is sent to the fire control cabinet. After the fire control center receives the fire alarm signal, the heavy gas signal, the circuit breaker trip signal, it starts the oil injection nitrogen injection system, discharge the oil and pressure to prevent the transformer explosion; at the same time, the cut-off valve under the oil storage cabinet is automatically closed, the oil tank is cut off to the transformer oil tank, and the transformer oil tank oil level is reduced. After a certain delay (usually 3S to 20s), the nitrogen release valve is opened, nitrogen is injected through the bottom of the transformer box through the nitrogen injection pipe, stirring the transformer oil and isolating the air, so as to achieve the purpose of fire and fire extinguishing.

联系方式

  1. 公司名称:XXX
  2. 电话:XXX
  3. 手机:XXX
  4. 联系人:XXX
  5. 地址:XXX

版权 © 保定电气厂  网址:http://miehuo.37ix.com.cn 推荐:变压器排油注氮灭火装置、变压器充氮式灭火器

网站建设及优化保定遨游网络公司