开启排油阀和注氮阀进行自动灭火
装置运行
Device operation
调试完毕,即进入运行工作状态。
After debugging, it will enter the working state.
在灭火装置运行工作期间应注意观察控制屏上信号灯的指示,一旦发现不正常的信号,河北变压器排油注氮灭火装置,应立即查看变压器。当变压器发生火灾时,应首先把变压器从电网中切除,如灭火装置处在自动灭火状态下,油浸变压器排油注氮灭火装置,装置将开启排油阀和注氮阀进行自动灭火;如变压器需要手动灭火,将方式选择开关置于手动位置,按下手动启动按钮SB3,强制起动灭火装置。
During the operation of the fire extinguishing device, attention should be paid to the indication of the signal lamp on the control screen. Once abnormal signals are found, the oil drainage and nitrogen injection fire extinguishing device of Hebei transformer should be checked immediately. When the shusongdaix.07858.net shusongdaic.07858.net shusongdair.07858.netshusongdaip.07858.net shusongdaik.07858.net shusongdaiz.07858.net transformer is in fire, the transformer should be removed from the power grid first. If the fire extinguishing device is in the state of automatic fire extinguishing, the oil-immersed transformer oil-draining and nitrogen-injecting fire extinguishing device will open the oil-draining valve and nitrogen-injecting valve for automatic fire extinguishing. If the transformer needs to fire extinguishing manually, put the mode selection switch in the manual position, press the manual start button SB3, and force the fire extinguishing device