灭火器拆卸操作规程
Operational Rules for Disassembly of Fire Extinguishers
1.1  经外观检查合格后的灭火器进行拆卸操作。
1.1 Dismantling the fire extinguisher after passing the appearance inspection.
1.2  拆卸前应逐具填写维修前信息记录表,包括灭火器用户名称、制造厂名称、气瓶(筒体)生产连续序号、灭火剂的种类、灭火级别和灭火种类、驱动气体名称、数量或压力,水压试验压力等。
1.2 before disassembly, the pre maintenance information record form shall be filled in one by one, including the user name of the fire extinguisher, the name of the manufacturer, the serial number of the cylinder (cylinder) production, the type of the fire extinguishing agent, the fire extinguishing level and type, the name, quantity or pressure of the driving gas, and the hydrostatic test pressure, etc.
1.3  拆卸灭火器时,应采用安全方法,确定安全防护措施,并应在确认内部无压力时方可进行。
1.3 When disassembling fire extinguishers, safety methods should be adopted to determine safety protection measures, and only when no internal pressure is confirmed can it be carried out.
1.4  拆卸时,首先观看压力表显示有无压力,有压力的先用扳手扳动压力表,听到出气时,停止松动,让压力缓慢释放。
1.4 When disassembling, first watch the pressure gauge to show whether there is pressure. When there is pressure, first use a wrench to pull the pressure gauge. When you hear the exhaust, stop loosening and let the pressure release slowly.
1.5  压力表显示无压力时,同样应注意安全,应先松动压力表,若无放气声,拧下压力表,再拆下喷粉胶管,缓慢拧下器头或阀门,以免发生危险。
1.5 Pressure gauge shows no pressure, the same safety should be paid attention to, should first loosen the pressure gauge, if there is no exhaust sound, unscrew the pressure gauge, then remove the powder injection hose, slowly unscrew the head or valve, in order to avoid danger.